For trunking, we provide variety, all accessories and the infrastructure you need
Designing the most practical and aesthetically pleasing solution for the interior cabling structure of a building is often the shared challenge of installers working in close consultation with engineering consultants and interior architects. Having access to a wide variety of trunking solutions is vital for you, the installer, as this allows to you present options and offer the best-possible solutions for the task at hand.
Trunking adds tidiness and order to any cabling environment and is a long-term strategy in cabling design. Making sound choices and applying top-quality products are pivotal. We offer you bulk stock of all products needed and we have the infrastructure to maintain large projects and get supplies to you whenever you need and wherever you are operating.
For the purpose of enclosure and protection of cable, trunking is used for channeling cable throughout the interior of office buildings, industrial premises and domestic environments. Professional-standard trunking products are used by electricians and by installers of data, fibre, CCTV cameras as well as domestic connectivity solutions. The main types of trunking available are PVC trunking and galvanised wiring channel (P).
Types of trunking
Standard, PVC trunking is available in two varieties: slotted and half-moon. These are used as a basic means of channeling interior cabling. PVC trunking is mainly used in the installation of air conditioning and for cable channeling in offices, industrial environments and in homes. Available in white and grey, PVC half-moon trunking is applied on floors only as it is easy to walk over and prevents tripping. This type of trunking contains two to four compartments for separate cable structuring.
Slotted trunking is used for the protection and consolidation of cable in various types of application where the cable needs to remain visible throughout the cable channel, such as in data centres. The slots allow for the easy re-channeling of cable, from in-between the slots, where needed. This type of trunking is available in standard grey PVC.
Galvanised wire trunking provides stronger cable protection, where required, and is also heat resistant. This type of trunking is often requested for the aesthetic appeal it adds to cable structuring.

What we supply
For the professional application of trunking, we supply all the variants of products and all necessary accessories such as end caps, right angles and joiner clips. All our trunking products and accessories are manufactured locally and are SABS approved.

PVC: Compact, miniature
YT 1
Dimensions: 16mm X 16mm.
Standard length: 2m.
YT 2
Dimensions: 25mm X 16mm.
Standard length: 3m.
YT 3
Dimensions: 40mm X 16mm.
Standard length: 3m.
YT 4
Dimensions: 40mm X 25mm.
Standard length: 3m.
YT 5
Dimensions: 40mm X 40mm.
Standard length: 3m.
PVC: Regular trunking
NBT/4 single-compartment
Dimensions: 100mm X 40mm.
Standard length: 3m.
NBT/4/ TC twin-compartment
Dimensions: 100mm X 40mm.
Standard length: 3m.
Corner trunking
Dimensions: 55mm X 30mm.
Standard length: 3m.
PVC: Half-moon trunking
Two-compartment
Dimensions: 48mm X 13mm and 70mm X 18mm. End cap available on request.
Three compartment
Dimensions: 48mm X 13mm and 70mm X 18mm.
Four compartment
Dimensions: 48mm X 13mm and 70mm X 18mm.
PVC: Industrial cable trunking
All in grey and available in white, on request.
CLT1
Dimensions: 50mm X 50mm.
Standard length: 3m.
CLT2
Dimensions: 75mm X 50mm.
Standard length: 3m.
CLT3
Dimensions: 75mm X 75mm.
Standard length: 3m.
CLT4
Dimensions: 100mm X 50mm.
Standard length: 3m.
CLT5
Dimensions: 100mm X 75mm.
Standard length: 3m.
CLT6
Dimensions: 100mm X 100mm.
Standard length: 3m.
PVC: Slotted trunking
Available in standard grey.
Standard length: 2m.
- Width: 25mm. Height: 25mm.
- Width: 25mm. Height: 40mm.
- Width: 25mm. Height: 60mm.
- Width: 25mm. Height: 80mm.
- Width: 40mm. Height: 40mm.
- Width: 40mm. Height: 60mm.
- Width: 40mm. Height: 80mm.
- Width: 60mm. Height: 40mm.
- Width: 60mm. Height: 60mm.
- Width: 60mm. Height: 80mm.
- Width: 80mm. Height: 40mm.
- Width: 80mm. Height: 60mm.
- Width: 80mm. Height: 80mm.
- Width: 100mm. Height: 60mm.
- Width: 100mm. Height: 80mm.
Galvanised wire trunking
P 1000
Thickness: 2.5mm. Mss kg/m: 3.0.
Standard length: 5m.
Dimensions: 41mm X 41mm.
P 3300
Thickness: 2.5mm. Mss kg/m: 1.8.
Standard length: 6m.
Dimensions: 41mm X 21mm.
P 2000
Thickness: 1.5mm. Mss kg/m: 1.0.
Standard length: 5m.
Dimensions: 41mm X 41mm.
P 4000
Thickness: 2.5mm. Mss kg/m: 1.6.
Standard length: 5m.
Dimensions: 41mm X 21mm.
P 1184
Thickness: 0.6mm. Mss kg/m: 0.5.
Standard length: 2.4m
Trunking and covers
P 800
Thickness: 0.6mm. Mss kg/m: 1.2.
Standard length: 3m.
Dimensions: 76mm X 76mm.
P 8300
Thickness: 0.8mm. Mss kg/m: 1.4.
Standard length: 3m.
Dimensions: 76mm X 63mm.
P 8200
Thickness: 0.8mm. Mss kg/m: 0.95.
Standard length: 3m.
Dimensions: 76mm X 50mm.
P 8184
Thickness: 0.6mm. Mss kg/m: 0.6.
Standard length: 3m.
P 9000
Thickness: 0.8mm. Mss kg/m: 1.9.
Standard length: 3m.
Dimensions: 127mm X 76mm.
P 9184
Thickness: 0.6mm. Mss kg/m: 0.82.
Standard length: 3m.
P 2200
Thickness: 0.8mm. Mss kg/m: 1.0.
Standard length: 3m.
Dimensions: 50mm X 50mm.
P 2184
Thickness: 0.8mm. Mss kg/m: 0.5.
Standard length: 3m.
The knockouts for P 8300 trunking fit 3 pin 5 amp plug sockets. Knockouts are placed at 750mm centres, staggered.
The 20mm knockouts for P 2200 trunking are spaced at 152mm centres, staggered.
Solid accessories
- Internal elbows.
- External elbows.
- Horizontal elbows.
- Internal splices.
- End caps.
- Three-way tees.
- Four-way crossovers.
- Hangers.
- Flange hangers.
- Purlin hangers.
- Brass fluorescent adaptors (20mm).
- Nylon fluorescent adaptors (20mm).